What we know about the measurement:
Meyer Sound Acheron 100 is a active cinema speaker .
- Quality of the measurement data is medium .
- Origin of the data is Vendors-Meyer Sound .
- Format of the data is .
- -3dB (resp. -6db) point v.s. reference is at 40.0Hz (resp. 38.7Hz).
- Reference level is normalised to 0.1dB computed over the frequency range [300.0Hz, 5000.0Hz].
- Frequency deviation is 2.8dB over the same frequency range.
- Directivity
- Horizontal directivity is (-50.0°, 50.0°) between 1kHz and 10kHz. Angle computed for +/-6dB.
- Vertical directivity is (-30.0°, 30.0°) between 1kHz and 10kHz. Angle computed for +/-6dB.
- Tonality (Preference) Score
- Tonality (Preference) Score is 4.3
and would be 6.0 with a
perfect subwoofer.
- Details: NBD: ON 0.57, LW 0.49, SP 0.62, PIR 0.55; SM: SP0.76, PIR0.61; LFQ 2.6, LFX 37Hz
- Tonality (Preference) Score is 5.7
with an EQ and would be 7.4 with a
perfect subwoofer and the same EQ.
- Details: NBD: ON 0.44, LW 0.39, SP 0.51, PIR 0.43; SM: SP0.92, PIR0.91; LFQ 2.6, LFX 35Hz
- Tonality (Preference) Score is 4.3
and would be 6.0 with a
perfect subwoofer.
- Note: Data provided by Meyer is high quality above 50Hz-100Hz