- Quality of the measurement data is medium.
- Origin of the data is L-Acoustics.
- Format of the data is a GLL file .
-
Sensitivity:
- Measured: 94.6 dB (avg. 300Hz-3kHz for 2.83V estimated at 1m).
- Measured: 74.6 dB computed at the measurement distance (10.0m) over the same frequency range.
- -3dB (resp. -6db) point v.s. reference is at 128.0Hz (resp. 109.0Hz).
- Reference level is normalised to -0.3dB computed over the frequency range [300.0Hz, 5000.0Hz].
- Frequency deviation is 2.2dB over the same frequency range.
- Tonality (Preference) Score
- Tonality (Preference) Score is 3.11
and would be 6.89 with a
perfect subwoofer.
- Details: NBD: ON 0.373, LW 0.348, SP 0.363, PIR 0.332; SM: SP0.714, PIR0.487; LFQ 1.844, LFX 109Hz
- Tonality (Preference) Score is 3.11
and would be 6.89 with a
perfect subwoofer.