- Quality of the measurement data is low.
- Origin of the data is Perlisten.
- Format of the data is .
-
Sensitivity:
- Company: 87.4 dB
- Measured: 87.0 dB (avg. 300Hz-3kHz for 2.83V measured at 1m).
- -3dB (resp. -6db) point v.s. reference is at 85.8Hz (resp. 74.1Hz).
- Reference level is normalised to 0.5dB computed over the frequency range [300.0Hz, 5000.0Hz].
- Frequency deviation is 1.8dB over the same frequency range.
- Tonality (Preference) Score
- Tonality (Preference) Score is 4.61
and would be 7.64 with a
perfect subwoofer.
- Details: NBD: ON 0.417, LW 0.377, SP 0.339, PIR 0.301; SM: SP0.887, PIR0.821; LFQ 1.231, LFX 73Hz
- Tonality (Preference) Score is 5.72
with an EQ and would be 8.41 with a
perfect subwoofer and the same EQ.
- Details: NBD: ON 0.321, LW 0.267, SP 0.284, PIR 0.226; SM: SP0.957, PIR0.952; LFQ 1.13, LFX 61Hz
- Tonality (Preference) Score is 4.61
and would be 7.64 with a
perfect subwoofer.
- Link to original Review: vendor review. .
- Note: Warning: measurements provided by vendor (Perlisten) are smoothed.