- Quality of the measurement data is high.
- Origin of the data is ASR.
- Format of the data is generated by a Klippel NFS .
- -3dB (resp. -6db) point v.s. reference is at 71.8Hz (resp. 63.0Hz).
- Reference level is normalised to 0.1dB computed over the frequency range [300.0Hz, 5000.0Hz].
- Frequency deviation is 3.3dB over the same frequency range.
- Tonality (Preference) Score
- Tonality (Preference) Score is 4.63
and would be 7.38 with a
perfect subwoofer.
- Details: NBD: ON 0.275, LW 0.243, SP 0.262, PIR 0.225; SM: SP0.343, PIR0.455; LFQ 0.301, LFX 62Hz
- Tonality (Preference) Score is 6.03
with an EQ and would be 8.55 with a
perfect subwoofer and the same EQ.
- Details: NBD: ON 0.241, LW 0.198, SP 0.211, PIR 0.164; SM: SP0.69, PIR0.845; LFQ 0.301, LFX 55Hz
- Tonality (Preference) Score is 4.63
and would be 7.38 with a
perfect subwoofer.
- Link to original Review: asr review. Links to other reviews: adh review , sos review .